Stramit® Metallic Monopanel® Cladding

Specifications

Stramit Monopanel® wall cladding has an appealing smooth faced finish with concealed fixings, designed for feature walling and is effective in both horizontal and diagonal applications.                             

Features

  • 250mm Cover – allows for quick installation.
  • Simple Installation – "fix, hinge and cover and fix again" procedure.
  • Versatility – can be used in either vertical, diagonal or horizontal applications.
  • Secret Fixing – fasteners are concealed from view to give a smooth appearance.
  • Trims – a complete range of trims and accessories are available.
  • Continuous Interlock – to weatherseal all joints.
  • High Tensile Steel – for greater damage resistance and performance.

Accessories

A range of flashings, trims and moulds are available for use with Stramit Monopanel®wall cladding. Starter clips (P3) are also available.

Material

Stramit Monopanel® wall cladding is a cold roll formed steel product in G550 base material (550 MPa minimum yield stress) with zinc-aluminium alloy substrate in accordance with AS1397 and colour coating available in a range of colours.

STRAMIT MONOPANEL® WALL CLADDING - SHEETING MASS (kg/m2 of roof area)
thickness BMTZincalume®Colorbond®
0.48mm4.514.58

Design

Pressures

STRAMIT MONOPANEL® WALL CLADDING – SERVICEABILITY LIMIT STATE CAPACITY
span
type
pressure (kPa) at the spans (mm) shown
600900120015001800210024002700
internal4.573.062.301.841.541.321.151.02
equal4.573.062.301.841.541.321.151.02
double5.193.472.612.091.741.491.311.16
STRAMIT MONOPANEL® WALL CLADDING – STRENGTH LIMIT STATE CAPACITY
span
type
pressure (kPa) at the spans (mm) shown
600900120015001800210024002700
internal7.294.463.192.482.031.721.491.31
equal7.294.463.192.482.031.721.491.31
double8.175.003.582.782.281.921.671.47

Tables are based on testing to AS1562 and AS4040 parts 0, 2 and 3. Internal spans must have both end spans 20% shorter.Values only valid for use with steel support members of 0.75mm or thicker.

Impact

For wall areas likely to be subject to human impact, sheeting spans should be reduced. Impact loads will vary considerably and these are not prescribed in Australian Standards. A maximum span of 1200mm is suggested for such areas, but this should be adjusted dependent upon the exposure and importance of the application.

Installation

Installation

All fasteners should conform to AS3566 – Class 3 and be completely compatible with the cladding material used. 

For steel
- No. 10 x 16mm wafer head self-drilling, self-tapping screws.
- 3.2mm aluminium rivet.
For timber
- No. 10 x 25mm (35mm for softwood) wafer head self-drilling type 17 screws.

Fastener Positions

Use one fastener per sheet at each support placed in the pre-punched slots.

 

For further installation information see the section later in this manual.

Availability

Product Availability 

NSWACT TAS VIC SA WA QLD NT
YYNYYNNN

Y - Yes     N - No     S - Subject to project size

Alternatives